Alarm board for the patent pending, HUG Hydronics system. Alarm board option provides a buzzer and dry contacts for remote alarming.


The buzzer will alarm when any pump fuse expires or low water is detected.  If power is lost to the system the normally open dry contact will close to indicate an alarm for the system.

Key Features

  • Alarm Buzzer with soft or loud buzzer setting
  • Alarms when there is low water in the tank
  • Alarms when any of the fuses expire
  • Dry contact relay for remote alarming when power is lost to the system

SPECIFICATIONS

Overall Dimensions & Weight

2” long x 2” wide x 0.44” tall (50.7mmx50.7mm); <0.1lb

Power Input

12VDC 

Relay Voltage

30VDC; 24VAC

Relay Contact Ratings

2A at 30 VDC

Relay type

1 Normally open and 1 normally closed

Buzzer settings 

Soft or loud buzzer setting

Part number

1118-01-AF




ALARM BOARD INSTALLATION STEPS

  1. Remove the (2) screws in the alarm board area of the control board and insert the (2) 15mm stand-offs provided.
  2. Mount the alarm on the stand-offs re-using the 2 screws.
  3. Adjust volume of the buzzer using the J3 jumper.  Jumpering Pins 1 to 2 provides the loudest setting, Pins 2 to 3 the softest setting and Pins 3 to 4 are for off.
  4. Connect wires to the J2 connector for remote alarm (optional).  Pin 3 is open during an alarm, Pin 2 is the common and Pin 1 is closed during an alarm.